Solar Panel Charging Controller with Timer,
12V/24V DC Auto Detect, 4 Amp
Solid State — Charges While LEDs in Use — Hi/Lo Battery Protection

Go to Solar Panels, 5Watts to 50 Watts SolarPowered
  Specifications
Nominal Voltage: 12V
Maximum charge current: 4A
Maximum load current: 4A
Over-discharge protection: 10.8V
Reset: 11.6V
Overcharge protection: 14.7V
Restart of charging: 13.7V
Self-consumption: 6mA
Operating temperature: -20°C to +80°C
Waterproof: IP22
Sun Level Adj.: 0-7
Timer: 0 to 15 hours
Dimensions: 4.1in.(W)×1.8in.(D)×1.1in.(H)
[105mm(W)×46mm(D)×28mm(H)]
Weight: 3.5oz [100 g]
  Applications
Solar Power Charge Controller for 5W, 10W and 25W Solar panels.
To order the item please click checkbox, then click red ORDER button and enter the quantity in the Shopping Cart
SLR-CONTROLLER-004 
$44.70ea (Min. Order 1 Pc)
 Features  
Timer control
12V/24V system auto detect
Temperature compensation
PWM charging
Low overhead power consumption
Reversed battery connection protection
All solid-state circuitry, no relays to fail
Ambient light sensor (using the solar panel as a type of light sensor) with adjustable set point
Click here to Solar Panel Charging Controller PDF manual. (1.10MB)
Note: To adjust the timer, please see the following chart for the DIP-switch settings.
Timer settings chart
Timer hours
No.5
No.6
No.7
No.8
Remark
0
OFF
OFF
OFF
OFF
TIMER OFF
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
Default setting
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
Keep Number 1 switch at OFF location.
New setting will take effect after restart (disconnection and reconnection of the battery).

Power to lights may be programmed to turn ON at different ambient light conditions. Programming is accomplished by setting the DIP switch, positions 2, 3, and 4. Refer to the chart below. If it is desired to turn ON the lamp/load only during dark conditions, set the DIP switch to CDS Light Sensor Degree 1, 2, or 3. If it is desired to turn ON the lamp/load under more illuminated conditions, set the DIP switch to CDS Light Sensor Degree 4, 5, 6, or 7.

To disable the ambient light sensor — thus providing power to the lamp/loads all the time — set the DIP switch for the CDS-Light-Sensor Degree to “0”.

To enable the CDS Light Sensor Degree selections, it is necessary to remove the battery connections for 10 seconds and reconnect. The solar panel is utilized as the CDS Light Sensor.

Light sensor chart
CDS ( Light sensor degree )
No.2
No.3
No.4
Light sensor degree
0
OFF
OFF
OFF
NO LIGHT SENSOR
1
ON
OFF
OFF
 
2
OFF
ON
OFF
3
ON
ON
OFF
Default settings CDS=3
4
OFF
OFF
ON
 
5
ON
OFF
ON
6
OFF
ON
ON
7
ON
ON
ON

Typical installation connection wiring diagram
Typical installation connection wiring diagram

Specifications subject to change without notice

23105 Kashiwa Ct, Torrance, CA  90505 - PH:  (800) 579-4875/(310) 534-1505 - FAX: (310) 534-1424
All images and pictures and text on our website is Copyrighted property of LEDtronics.
No-one is authorized to use our pictures, images, catalogs or text without our explicit written approval.
© Copyright 1997-2008 LEDtronics, Inc. All Rights Reserved - Contact Us