Note: If a lamp is being replaced, and it had an external ballast wired between the power source and the socket, the ballast needs to be bypassed (Operating Voltage 100 to 277 VAC). LEDtronics recommends removing the old ballast to prevent any accidental reconnection with LED lamps.
When Installing Lamps In Potentially Corrosive Outdoor Environments
LEDtronics suggests that a silicone moisture-barrier sealant be used to protect the metal-threaded base of the LED bulb.
Sealant is highly recommended for all outdoor-environment LED bulb installations to prevent water and/or moisture incursion that can lead to premature degradation of the bulb base and eventual bulb failure. This is
especially recommended for LED bulb installations
near saltwater bodies.
Dow Corning Molykote 111 Valve Lubricant and Sealant is a high-temperature, moisture-resistant, silicone grease. If liberally applied to the clean surface of the lamp socket and the base of the lamp itself, it will provide moisture and corrosion resistance.
Dow Corning's material spec sheet for Molykote 111 Valve Lube & SealantWhite LED technology is patent protected in the US. LEDtronics White LED products are covered under these patents.